dc.description.abstractThis dissertation discusses the application of the Active Disturbance Rejection Control (ADRC) method applied to three-phase converters connected to the electrical grid. The proposed method aims to compensate for system parametric uncertainties and reject external disturbances. Application approaches will be presented, one of which is the design of a current mode control for a three-phase voltage source converter system, and in this approach, a variant of the traditional ADRC scheme is used. In this way, the approach intends to generate a comparison with the classical control approach, both in synchronous coordinate and also in stationary. Theoretical studies are presented and simulation results are discussed based on tests carried out in the Simulink computational environment, the MATLAB software, and also the EMTP-RV software.en
dc.description.abstractEsta dissertação discute a aplicação do método de Controle com Rejeição Ativa de Distúrbios (ADRC) aplicado em conversores trifásicos conectados à rede elétrica. O método proposto tem o objetivo de compensar incertezas paramétricas do sistema e rejeitar perturbações externas. Serão apresentadas abordagens de aplicações, sendo uma delas o projeto de um controle de modo de corrente para um sistema trifásico conversor de fonte de tensão, e nesta abordagem é utilizado uma variante do esquema ADRC tradicional. Deste modo, a abordagem pretende gerar uma comparação com a abordagem de controle clássica, tanto em coordenada síncrona, como também em coordenada estacionária. São apresentados estudos teóricos e resultados de simulação são discutidos a partir dos ensaios realizados em ambiente computacional Simulink, do software MATLAB, e também no software EMTP-RV.pt
dc.description.refereeCount5
dc.format.pages85
dc.hasResearchProjectInstrumentação Inteligente e Controle Avançado de Sistemas Incertos
dc.identifier.capes31022014004P3
dc.identifier.lattesAdvisor3410411498624892
dc.identifier.lattesReferee13410411498624892
dc.identifier.lattesReferee34369644894024711
dc.identifier.lattesReferee57976857463182643
dc.identifier.orcidAdvisor0000-0002-5671-5588
dc.identifier.orcidAuthor0000-0002-4443-0251
dc.identifier.orcidReferee10000-0002-5671-5588
dc.identifier.orcidReferee30000-0002-0224-9323
dc.identifier.orcidReferee40000-0003-1102-422X
dc.identifier.orcidReferee50000-0002-7891-0034
dc.identifier.other15129006
dc.identifier.pg204014
dc.identifier.urihttps://repositorio.cefet-rj.br/handle/123456789/190
dc.language.isopt_BR
dc.publisherCENTRO FEDERAL DE EDUCAÇÃO TECNOLÓGICA CELSO SUCKOW DA FONSECA
dc.publisher.institutionCENTRO FEDERAL DE EDUCAÇÃO TECNOLÓGICA CELSO SUCKOW DA FONSECA
dc.publisher.institutionSiglaCEFET-RJ
dc.publisher.institutionSiglaAuthorCEFET-RJ
dc.publisher.programEngenharia Elétrica
dc.rightsAberto
dc.status.consistentSim
dc.subjectINSTRUMENTAÇÃO E CONTROLE
dc.subject.cnpqENGENHARIAS IV
dc.subject.concentrationSISTEMAS ELETRÔNICOS INDUSTRIAIS
dc.subject.keywordsCurrent control
dc.subject.keywordsRobust control
dc.subject.keywordsgrid-connected converters
dc.subject.keywordsThree-phase electrical system
dc.subject.keywordsADRC
dc.subject.keywords: Controle de corrente
dc.subject.keywordsControle robusto
dc.subject.keywordsconversores conectados à rede
dc.subject.keywordsSistema elétrico trifásico
dc.subject.keywordsADRC
dc.titleCONTROLE ROBUSTO DE CORRENTE DE CONVERSORES TRIFÁSICOS CONECTADOS À REDE REDE USANDO O MÉTODO ADRC
dc.typeDISSERTAÇÃO

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
CONTROLE_ROBUSTO_DE_CORRENTE_DE_CONVERSORES_TRIFÁSICOS_CONECTADOS_À_REDE_REDE_USANDO_O_MÉTODO_ADRC.pdf
Tamanho:
2.71 MB
Formato:
Adobe Portable Document Format